Thin Film Coating

Spin coater 9000 Spin coater 9500 Electrophoretic deposition (EPD) system 9000 EPD coating 9500 Sol gel coating system Chemical Vapour deposition DC magnetron sputtering system 9000 Thermal Evaporation system 9000 Spray pyrolysis system 9000 Thermal evaporation and Magnetron Sputtering 9000

Surface characterization

Contact angle 9000 Dip coater 9000 Film coater 9000

Electrical characterization

Four Probe Systems Sourcemeter Hall Effect System 9000 Solar cell I-V characterization I-V temperature Analyzer OLED characterization 9000 system Gas sensor analysis system Dielectric measurement system 9000 Impedance analyzer 9000 Capacitance-Voltage analyzer Electrical conductivity system 9000 Cryostat for optical measurements 9000 Cryostat for electrical measurement 9500 Thin film Transistor Characterization System Probe Holder 900 Probe Station 9000

Photoelectrical characterization system

Photoresponse 9000 Quantum Efficiency 9000 LED Quantum efficiency 9000

Mechanical Equipments

Tribometer 9000

Solar simulator

Solar Panel Simulator Reference Solar cell I-V and C-V probe holder 150 WW 80 Solar Simulator 9400 300 W 80 Solar Simulator 9800 300 W Solar Simulator 9800 450 W Solar Simulator 9800 450 W Solar Simulator 9800 version ll 9000 Solar Simulator 9000 Solar Simulator V1 AAA Class Solar Simulator 9400 AAA Class Solar Simulator 9800 AAA Class Solar Simulator 9920 AAA Class Solar Simulator 10000 FYTRONIX Solar Simulator 10X FYTRONIX Solar Simulator 2020 FYTRONIX Solar Simulator 7200 FYTRONIX Solar Simulator 7500 FYTRONIX Solar Simulator 8000 FYTRONIX Solar Simulator 9000 FYTRONIX Solar Simulator 9712 LED Solar Simulator 9620 LED Solar Simulator 9750 LED Solar Simulator 9800 LED Solar Simulator 9820 LED Solar Simulator 9830 LED Solar Simulator 9860 LED Solar Simulator 9872 LED Solar Simulator 9900 LED Solar Simulator 9920 Panel Solar Simulator 9620 Solar Simulator 2019 Solar Simulator 2020 v2 Solar Simulator 9000 v1 Solar Simulator 9600 Solar Simulator 9800 Solar Simulator 9900 Solar Simulator 10000 Solar Simulator 20202 Solar SM 9600 Motorized Stage UV 150W Solar Simulator UV VISIBLE Solar Simulator 7400 XENON 150W Sunscreen Solar Simulator XENON 300W Solar Simulator XENON Lamp System 9000

Power supply

Cancer Treatment

Hyperthermia Therapy system 9000

Spectroscopy Equipments

Optical constant analyzer 9000

Material Synthesis and Preparation

Hydrothermal 9000 Hydrothermal 9500 Ultrasonic sonicator Spark Plasma System Microwave Hydrothermal System

Press

Press 9000 Press 9000 Electric Press

Sample Preparation

UV ozone cleaner

Nanomaterial Production Systems

Nanomaterial production system Electrospin Electrospin 9300

Furnaces

High Temperature furnace 9000

Photocatalytic and Photochemical Systems

Photocatalytic 9000 Photocatalysis System PHC-9000 Photocatalysis System 9820

Electrochemistry systems

Cyclic voltammetry Electrodes Battery Charge and Discharge system 9000

Clean room Equipment

Glove box 9000

   NEW VERSATILE X-Y-Z ELECTROSPINNIG SYSTEM



FYTRONIX ELECTROSPINNINGSYSTEM includes

The Elektrospinning process uses high voltage to create an electric field between adroplet of polymer solution at the tip of a needle and a collector plate).

 

TheESP-XYZ is a complete electrospinning production system.

 

Youcan prepare the following materials

1.   Nanofiber(semiconductor, superconductor, insulator)

2.   Nanothin film

3.   Thinfilm applications

4.   Thinfilms for diode, photosensor, solar cells, transistor

 

 

 

 

SPECIFICATIONS

Electrospinning Machine

 

1. Substrate-Nanofiber-Substrate composite,

2. Fibre-substrate composite

3. Substrate-Fibre composite

4. XYZ coating

All these provisions should be available to makethe composite structure nanofibers of the size of 15 -15 cm2.

 

a)High  Voltage

 

1. Input voltage range: 210-240 VAC+/-

2. Output voltage range: 0 to 30 KV or 50 KV or60 KV

3. Output current: 0-400 μA preferable

4. Digital: Digital voltage and currentmonitoring should be available

5. Voltage Regulation: 1/10KV must needed

6. Overload trip- unit shut down if currentexceeds 20% of the maximum output current

7. Power requirement: 400 watt

 

 

b) Syringe Pump

1. Single syringe attachment with separatestepper drive unit 2. Infusion and withdrawal function optional

3. Volume, time and flow control preferable

4. Acceptable sample syringe: 5 μl-60 ml

5. Adjusting resolution: 0.1 μl/min or higherside

6. Flow rate: 1nl/min-3 ml/min or higher side

 

c) Collector

1. Plate: 200 mm x 200 mm is preferable 2. DumCollector: D=100 mm, L=200 mm 3. Disk: D=10 mm, L=200 mm

4. RPM: 300-1000 or more preferable

 

d) Spinneret

 

Co-axial nozzle (Stainless steel arrangementwith fixed needle geometry) Multi-nozzle (4 changeable nozzle geometry)

Single Nozzle

 

Linear stage

Both side X-Axis: Distance adjustment manual.Computer controlled preferred Y-Axis: Programmable transverse motion

Specification:

Oscillation speed: 1 mm/sec to 5 mm/secadjustable preferable

Stroke distance: 300 mm preferable

Speed: Three speed adjustment (Slow, Medium andFast) Z-Axis manual control optional

 

Spinning arrangement

Vertical spinning Horizontal spinning

Both side spinning is must

                                                  8

    g)Spinning conditions

1. Solvent spinning (Compatible for water,Acetone, Methanol and other solvents)

 

h) Spinning chamber

Temperature control and display (up to 60 degreeCelsius)

Humidity display and controller

Ventilation for fumes

Illuminating Light:20 Wx2 LED tubes

UV Light: 50 watts

Computer control interface

 

i) Panel control

Emergency stop

Main stop

UV light arrangement

Exhaust Operation

Auto cut high voltage while door is opened.

 

 

 

j) Accessories

Foot pad: 1 number

 Insulation pad: 1 number

 Standard spinning samples

Chemical resistance tubing

 Tube connectors

 

k) Additional Accessories

Syringes with needles: 3ml and5ml

Aluminum Foils

Blower

 

l) Precession syringe pump for micro-fluidicapplications

The pump should have independent controller withsoftware based applications

Warranty 01 year

Annual Maintenance Charges: AMC will be charged after completionof Warranty period for 5 years Demonstration of the setup is necessary afterinstallation

 

 

 

NEEDLES

Theneedles can be changed easily, many choices for diameter and length as follows,

Innerdiameter

27G=0.184mm

26G=25G=0.232mm

25G=0.232mm

24G=0.28mm

23G=0.317mm

22G=0.39mm

21G=0.49mm

20G=0.56mm

18G=0.79mm

16G=1.10mm

14G=1.60mm

 

 

REAL-TIME VISUALIZATION

THECAMERA is at the heart of Electro-Hydrodynamics atomization. In order to get asteady coaxial/simple electrospinning/electrospraying process, Taylor conesteadiness is required. CAMERA visualization is key for checking time-real heperformance of the process. Includes: Analog CCD Camera, Lens & Extensor,Camera Support, LED Illumination and VGA output to connect to most ofcommercial screens.

 

 

CHAMBER ILLUMINATION

LEDIllumination is equipped with all the securitymeasures, ensuring a safe operation for the user.

 

 

ROTATING COLLECTOR

Rotatingcollector of electrospinning is used for collecting aligned nanofiber sheet.This is the simplest and effective method to make aligned nanofibers. By usingdifferent length/ diameter ratio, with different rotating speed, an even fibersheet or aligned fibers can be made.

Elektrospinning Machine

  • Product Code: ELECTROSPINNING_SYSTEM_002
  • Availability: In Stock
  • 0.00TL

1. Nanofiber (semiconductor, superconductor, insulator)
2. Nano thin film
3. Thin film applications
4. Thin films for diode, photosensor, solar cells, transistor