Thin Film Coating

Spin coater 9000 Spin coater 9500 Electrophoretic deposition (EPD) system 9000 EPD coating 9500 Sol gel coating system Chemical Vapour deposition DC magnetron sputtering system 9000 Thermal Evaporation system 9000 Spray pyrolysis system 9000 Thermal evaporation and Magnetron Sputtering 9000

Surface characterization

Contact angle 9000 Dip coater 9000 Film coater 9000

Electrical characterization

Four Probe Systems Sourcemeter Hall Effect System 9000 Solar cell I-V characterization I-V temperature Analyzer OLED characterization 9000 system Gas sensor analysis system Dielectric measurement system 9000 Impedance analyzer 9000 Capacitance-Voltage analyzer Electrical conductivity system 9000 Cryostat for optical measurements 9000 Cryostat for electrical measurement 9500 Thin film Transistor Characterization System Probe Holder 900 Probe Station 9000

Photoelectrical characterization system

Photoresponse 9000 Quantum Efficiency 9000 LED Quantum efficiency 9000

Mechanical Equipments

Tribometer 9000

Solar simulator

Solar Panel Simulator Reference Solar cell I-V and C-V probe holder 150 WW 80 Solar Simulator 9400 300 W 80 Solar Simulator 9800 300 W Solar Simulator 9800 450 W Solar Simulator 9800 450 W Solar Simulator 9800 version ll 9000 Solar Simulator 9000 Solar Simulator V1 AAA Class Solar Simulator 9400 AAA Class Solar Simulator 9800 AAA Class Solar Simulator 9920 AAA Class Solar Simulator 10000 FYTRONIX Solar Simulator 10X FYTRONIX Solar Simulator 2020 FYTRONIX Solar Simulator 7200 FYTRONIX Solar Simulator 7500 FYTRONIX Solar Simulator 8000 FYTRONIX Solar Simulator 9000 FYTRONIX Solar Simulator 9712 LED Solar Simulator 9620 LED Solar Simulator 9750 LED Solar Simulator 9800 LED Solar Simulator 9820 LED Solar Simulator 9830 LED Solar Simulator 9860 LED Solar Simulator 9872 LED Solar Simulator 9900 LED Solar Simulator 9920 Panel Solar Simulator 9620 Solar Simulator 2019 Solar Simulator 2020 v2 Solar Simulator 9000 v1 Solar Simulator 9600 Solar Simulator 9800 Solar Simulator 9900 Solar Simulator 10000 Solar Simulator 20202 Solar SM 9600 Motorized Stage UV 150W Solar Simulator UV VISIBLE Solar Simulator 7400 XENON 150W Sunscreen Solar Simulator XENON 300W Solar Simulator XENON Lamp System 9000

Power supply

Cancer Treatment

Hyperthermia Therapy system 9000

Spectroscopy Equipments

Optical constant analyzer 9000

Material Synthesis and Preparation

Hydrothermal 9000 Hydrothermal 9500 Ultrasonic sonicator Spark Plasma System Microwave Hydrothermal System

Press

Press 9000 Press 9000 Automatıc Press

Sample Preparation

UV ozone cleaner

Nanomaterial Production Systems

Nanomaterial production system Electrospin Electrospin 9300

Furnaces

High Temperature furnace 9000

Photocatalytic and Photochemical Systems

Photocatalytic 9000

Electrochemistry systems

Cyclic voltammetry Electrodes Battery Charge and Discharge system 9000

Clean room Equipment

Glove box 9000
  • GAS SENSOR MEASUREMENT SYSTEM

   GAS SENSOR MEASUREMENT SYSTEM


FYTRONIX RESISTIVE GAS SENSOR MEASUREMENT SYSTEM
(FYTRONIX FY-7000)
 
Technical Data

1. Current-time characteristics of gas sensor
2. Resistance-time characteristics of gas sensor
3. Gas chamber 
4. Gas type: Carbon  Co2 karbondioksit, karbon monooksit, Air, 
5. Temperature controlling of sample holder from room temperature  to 150 oC or more
6. Sample holder 
7. Automatic temperature controller
8. Sourcemeter
Current range: 50 PA-250  mA 
Voltage  range:0-20 V or more
9. All in one computer
10. Software 


SPECIFICATIONS OF THE SYSTEM
1. The system measures automatically current-time characteristics of gas sensors
2. The system measures automatically resistance-time characteristics of gas sensors
3. The system measures automatically response-time characteristics of gas sensors
Specifications of Gas sensing system

11. Gas sensing system should has gas flowmeter, sourcemeter, cryostat, and software
12. Mass flowmeter should has the followings
Flow meter range:  0–5000 SLPM 
Steady state control range: 0.01% – 100% of full scale
Standard accuracy calibration, NIST-traceable: ±0.6% of reading or ±0.1% of full scale
Optional high-accuracy calibration, NIST-traceable: ±0.5% of reading or ±0.1% of full scale
Repeatability: ±(0.1% of reading + 0.02% of full scale)
Typical control response time: as fast as 30 ms
Warm-up time: <1 s
13. Sourcemeter should has the followings
Voltage range: 0- 48 V
Current range: 10 nA-500 mA
USB communication

14. Cryostat
Temperature range: RT- 400 K
PID controlling 
Heating rate controlling
USB communication
Heating holder
15. Software should has the followings
To measure resistance-time characteristics of gas sensor
To measure response-time characteristics of gas sensor
Inputs of software should be
Bias voltage
Measurement count
Delay time
Gon/Goff (Gas on and Gas off)
Step count
Heating Rate
Gas PPM configuration ( for various gas concentration)
16. All in one computer

GAS SENSOR MEASUREMENT SYSTEM

  • Product Code: GAS SENSOR MEASUREMENT SYSTEM
  • Availability: In Stock
  • 0.00TL