DIELECTRIC MESUREMENT SYSTEM HIGH TEMPERATURE 600
- Product Code: DIELECTRIC-mesurement-system-high-temperature-600
- Availability: In Stock
Visual is for representation purposes only. It will be changed according to the specificitions
Overview
HIGH TEMPERATURE DIELECTRIC MEASUREMENT SYSTEM
RT–600 °C Four-Probe Sample Stage & LCR Meter
Integration
An end-to-end dielectric and
impedance analysis solution designed for material science, semiconductor
research and development, and high-temperature material characterization. The
system integrates a high-precision LCR meter, a specialized atmospheric
heating stage, and comprehensive control software into a unified platform.
SYSTEM OVERVIEW & KEY FEATURES
Providing precise temperature control from ambient up to
600 °C, this system enables real-time monitoring of temperature- and
frequency-dependent electrical properties of materials. Utilizing auto-balance
bridge technology and a 4-terminal pair configuration, it effectively
minimizes parasitic effects to deliver high-accuracy measurements.
Thermal
Control: High-stability heating stage utilizing resistance heating to
achieve rapid heating rates up to 150 °C/min and cooling rates up to 40
°C/min.
Heating rate: 1-
20 °C/min is suitable to measure dielectric measurements. We can provide a
furnace from rapid heating rates up to 150 °C/min and cooling rates up to 40
°C/min. But these heating rates are very high according ASTM standards.
Impedance Analysis: Simultaneous
analysis of 13 electrical parameters across a 20 Hz – 1 MHz frequency sweep.
Optical
Access: Features a easily removable and replaceable fused silica window
for optical access and reflection measurements.
Integrated Software & Automation: Lifetime-licensed dielectric testing software offering
multi-parameter graphic sweep capabilities and robust data storage.
Systems measure automatically dielectric constants at
various temperatures wiht any temperature step
TECHNICAL SPECIFICATIONS
1. Heating Stage & Chamber Specifications
Temperature Range: Ambient
(RT) to 600 °C
Temperature
Stability: ±0.1 °C
Max Heating
Rate: 150 °C/min is fvalid or a furnace
Max Cooling
Rate: 40 °C/min is a valid for a furnace. We will provide also heating
chamber for dielectric measurements.
Sample Holder: Silver,
23 mm × 23 mm or equivalent
Optical Path: Reflection
mode
Top Window: JGS2
Fused Silica Glass (Transmission Range: 220 nm – 2500 nm), Ø25 mm × 1 mm,
manually removable and replaceable
Chamber Height: 6.5
mm or equivalent according to IEC or ISO standards
Window-to-Sample
Distance: 7.5 mm (from upper window surface to upper sample surface) or a
suitable according to ASTM standards
Environment: Ambient
Atmosphere
Probe Assembly: 4
× Fixed Probe Holders + 4 × Gold-plated tungsten steel probes or equialent a
suitable according to ASTM standards
Interfaces: 4 ×
BNC probe ports or equivalent probes or equivalent a suitable according to
ASTM standards
2. Digital LCR Meter Specifications
Measured Parameters: |Z|,
|Y|, θ, Rp, Rs, G, X, B, Cp, Cs, Lp, Ls, D (tanδ)
Frequency
Range: 20 Hz – 1 MHz
Basic
Accuracy: ±0.05%
Measurement
Technology: Auto-balance bridge, 4-terminal pair
Display: 7-inch
TFT LCD (800×600 resolution)
Measurement
Speed: High-speed testing up to 5.6 ms
Range
Selection: Up to 15 measurement ranges
Current
Output: Up to 100 mA or Expandable
This is not
suitable for dielectric measurements. We will provide intenal voltage
source: -5 V to + 5V programmable output
Independent
Voltage Source: ±5V programmable output accoding to ASTM standards
Analysis
Functions: 201-Point List Sweep, Multi-Parameter Graphic Sweep,
Arithmetical Operations, 10-Bin Sorting with audio/visual alarm
Internal Storage: 100
groups of setup files, 10 groups of GIF image files
External
Storage: Up to 100 setup files via USB interface
Connectivity: USB
HOST, USB DEVICE, LAN, HANDLER, External DC Bias Control Interface
UNSPSC
Classification: Impedance meters
3. Data Acquisition & Processing Workstation
Hardware: Intel
Core i5 (10th/11th Gen or equivalent), 8 GB RAM, 512 GB SSD, 15-inch Full HD
display, 4–6 hours battery backup
Software: Lifetime-licensed
dielectric testing software with free updates
Accessories: Original
power adapter and all required communication cables
SCOPE OF SUPPLY & SERVICES
Complete System Package: Main heating stage unit, Digital LCR Meter, laptop
workstation, standard reference/calibration samples, all essential
accessories, and interface cables for immediate operation.
Installation
& Validation: Professional installation, system commissioning,
performance verification, and calibration certification.
Training
Services: Comprehensive online and on-site physical user training.
Documentation: User
manuals, technical documentation, and Standard Operating Procedures (SOPs).
Warranty & Support: Minimum two (02) years comprehensive warranty, lifetime
after-sales technical support, free software/hardware updates (where
applicable), and long-term availability of spare parts and consumables.