FYTRONIX ELEKTRONIK TEKNOLOJİLERİ A.S

300 W-50 AAA CLASS SOLAR SIMULATOR

  • Product Code: 300-W-50-AAA-CLASS-SOLAR-SIMULATOR
  • Availability: In Stock

  • 300 W-50 AAA CLASS SOLAR SIMULATOR

   300 W-50 AAA CLASS SOLAR SIMULATOR




Solar  simulators are manufactured in various style according to requested specifications

Solar simulator is used  for current-voltage (I-V) characteristic measurements is used Solar simulator for power-voltage (P-V) of solar cells measurements
FYTRONIX solar simulator  is manufactured in accordance with IEC 60904-9 2007, ASTM E 72-10, , JIS C 891 standards. 

Solar simulators are manufactured in various style according to requested specifications
Solar simulator for current-voltage (I-V) characteristic measurements 
Solar simulator for power-voltage (P-V) of solar cells measurements
FYTRONIX solar simulator is manufactured in accordance with IEC 60904-9 2007, JIS C 891 standards. 
SPECIFICATIONS
Solar simulator class:  AAA (Spacial non-Uniformity, Spectral Match, Temporal Instability)
Irradiance a (AM 1.5G 1 Sun = 100 mW/cm2 up to 2 SUN
 Target area 50 x 50 mm
 Xenon lamp: 300 W,  Xenon Short Arc, Ozone free
Working Distance (mm) 380 ± 15 mm
Shutter Manual Shutter
Attenuator Manual Variable Attenuator
 Dimensions (L×W×H) 500 × 175 × 180 mm and higher
Power Requirements Adjustable touchscreen power supply with 110-240V, 50Hz/60Hz,
Stability / Ripple / Regulation 0.05% / < 1% / 0.02% current variation for 5V line charge
Adjustable working distance
 Height adjustable stand allowing to adjust the working distance 
Warranty and Spares, Availability
 Provide one (01) year warranty and certificate for the availability of spares for 10 years.


 SOFTWARE  (optıonal) 
Software measure all photovoltaic parameters of solar cells by computer. The system determine all 
photovoltaic parameters. software of solar simulator system determine the following photovoltaic 
parameters such as solar simulator automatically determine the photovoltaic parameters as follows
Open circuit voltage (voc) 
Short circuit current (isc) 
Fill factor (ff)
Voltage at pmax (vmax) 
Current at pmax (imax) 
Maximum power output (pmax) 
Shunt resistance (rsh) •
Series resistance (rs) •
Characteristic resistance of solar cell (rch) • 
Photoreponse (RR)
Solar cell efficiency (n)
Certificate Compliance
07.082.021
Product: Solar Simulator Model: SOLAR TECH X-11 SN: 112 Applicable 
Standards: ASTM E 72-10, EIC 60904-9, JIS C 8912
Spectral Fit